This signal is output when the execution of direct data operation fails.
If direct data operation is executed when direct data operation cannot be executed (DCMD-RDY output is OFF), EXE-ERR turns ON.
The DCMD-RDY output will be turned OFF under the following conditions.
- The main power supply to the driver is turned off.
- The power cutoff function is activated
- An alarm has occurred
- C-ON input is OFF (when C-ON input is assigned)
- FREE input is ON
- STOP input is ON
- STOP-COFF input is ON
- PAUSE input is ON
- CLR input is ON
- Returning to origin in progress
- ZHOME in operation
- Teaching, remote operation, I/O test, download, configuration, backup, or restore is being performed on the MEXE02.
- Any of the following maintenance commands is being executed: "Configuration", "Bulk data initialization (excluding communication parameters)", "Bulk read of non-volatile memory", "Bulk initialization of all data (including communication parameters)", "Read of backup data", or "Write of backup data".