Cable Bend Radius
The bending radius varies depending on the cable type as follows:
Cable Type | Bend Radius |
---|---|
Lead Wire Type | At least 4 times the cable outer diameter |
Multi-core cable type | At least 6 times the cable outer diameter |
Flexible Cable | At least 6 times the cable outer diameter |
Please refer to the catalog for the external dimensions of the multi-core cable type.
The external dimensions of the lead wire type are not shown in the catalog, so please measure them yourself.
Please use a flexible cable when the cable is to be repeatedly bent. Please see here
for precautions when using a movable cable .
Note that the bending radius for lead wire types and multi-core cable types is the value when the cable is fixed in place, and not the value when the cable is bent repeatedly.